Threshold Signatures and BIP Questions

2 replies 148 views
im_bossNewbie
Posts: 4 · Reputation: 26
#1Oct 26, 2025, 01:29 PM
Hey, I’m trying to wrap my head around this BIP stuff. So there are two methods for making threshold signatures based on the number k, right? If k is set to 16, we go with OP_16, which I think is 0x60. What happens when k is 17? Is it 0x61 or 0x11? I’m confused because k equals 17 in this case... Thanks for any help!
3 Reply Quote Share
mr_apeNewbie
Posts: 139 · Reputation: 35
#2Oct 26, 2025, 05:33 PM
Alright, here’s my take. If you get into the code, you’ll see that it raises the limit for public keys to 999. For numbers beyond 16, they’re handled like usual but with a “minimal push” rule. So for 17, we use 0x0111. The 0x01 tells the interpreter to push a single byte, and then 0x11 represents 17. This way, numbers get pushed in the shortest form possible. Can’t wait to see what everyone thinks about this!
3 Reply Quote Share
im_bossNewbie
Posts: 4 · Reputation: 26
#3Oct 27, 2025, 02:29 PM
Thanks for clarifying that! But just to be sure, does this mean we can have a ton of pubkeys now? And what’s the reasoning behind this limit change? Seems kinda interesting.
0 Reply Quote Share