Ultimate Guide to Setting Up the SpondooliesTech SP30

21 replies 46 views
Posts: 23 · Reputation: 48
#1Aug 17, 2017, 11:56 PM
Here's a list of miners that I've set up before: ASICMiner Blade, Cube, Tube, Prisma, Avalons 2, 3, 4, 6, and SpondooliesTech models SP10, SP20, SP30, SP35, plus a few Technobit models and Bitmain AntMiners.
3 Reply Quote Share
john2015Full Member
Posts: 3 · Reputation: 684
#2Aug 18, 2017, 12:20 AM
Nice guide Dogie! But how does the noise of the SP30 at 4.5TH compare to the SP10?
4 Reply Quote Share
ape2013Senior Member
Posts: 59 · Reputation: 1641
#3Aug 18, 2017, 02:19 AM
Looks amazing! Can't wait to see it in action.
5 Reply Quote Share
Posts: 23 · Reputation: 48
#4Aug 18, 2017, 05:14 AM
The noise really comes down to the PSUs. SP30 is quieter and has a lower pitch compared to SP10 in quiet mode. Just a heads up for those running at 110V, you need at least 13A cables.
0 Reply Quote Share
Posts: 23 · Reputation: 48
#5Aug 18, 2017, 05:25 AM
That's interesting. But sometimes I wonder if beauty matters when we deal with power and heat issues. These chips could perform better with more power, and noise could drop significantly if we switched PSUs or went bigger.
2 Reply Quote Share
john2015Full Member
Posts: 3 · Reputation: 684
#6Aug 18, 2017, 06:44 AM
Sounds great! I'm using 230V, so I hope it works well.
4 Reply Quote Share
bridge2019Full Member
Posts: 1 · Reputation: 744
#7Aug 18, 2017, 10:27 AM
That first image looks off. It has ears and doesn’t match the other pics. Just saying.
2 Reply Quote Share
the_diamondFull Member
Posts: 1 · Reputation: 529
#8Aug 18, 2017, 11:50 AM
Totally agree! This one looks like a money maker. Let’s see how it performs next year. Nice setup, though!
2 Reply Quote Share
john2015Full Member
Posts: 3 · Reputation: 684
#9Aug 20, 2017, 11:31 PM
Yeah, the top models always get a glow-up.
1 Reply Quote Share
Posts: 23 · Reputation: 48
#10Aug 21, 2017, 05:26 AM
The first image was just a CAD design. Mine didn’t come out right, so I’m fixing the lighting. The real SP30 has different heatsinks and is silver, like the SP10.
4 Reply Quote Share
0xBearFull Member
Posts: 54 · Reputation: 631
#11Aug 21, 2017, 06:01 PM
If someone was unhappy with the SP10 noise, should we expect the same with the SP30 in warmer temps?
3 Reply Quote Share
Posts: 23 · Reputation: 48
#12Aug 21, 2017, 08:35 PM
Not really. It depends on your situation and how much noise bothers you. If you can keep doors closed, you might be fine.
2 Reply Quote Share
0xBearFull Member
Posts: 54 · Reputation: 631
#13Aug 22, 2017, 01:24 AM
Could you share an audio clip of it hashing? A comparison with the SP10 would be awesome.
4 Reply Quote Share
Posts: 68 · Reputation: 8
#14Aug 22, 2017, 05:04 AM
Thanks for the guide! The power cord you mentioned is a standard PC one, right? Comes with my 1300W PSUs. Is it only for 110V? What about 200-240V?
3 Reply Quote Share
grimb1tMember
Posts: 2 · Reputation: 73
#15Aug 24, 2017, 12:02 AM
You’ll need a cord that connects your receptacle to C13. Since it has two PSUs, a splitter might be tricky to find or you could use a PDU.
1 Reply Quote Share
Posts: 68 · Reputation: 8
#16Aug 24, 2017, 11:14 PM
I’m planning on using two outlets on different breakers. Running the numbers, an SP30 at 4.1TH at 2600W gives a better hash/Watt than 4.5TH at 2900W. Hash/Watt is what really counts.
3 Reply Quote Share
chris2017Full Member
Posts: 2 · Reputation: 433
#17Aug 25, 2017, 12:12 AM
Really? That’s surprising.
2 Reply Quote Share
Posts: 3 · Reputation: 17
#18Aug 25, 2017, 03:03 AM
@marvell1 You’re missing the point. What really matters is $/GH and the operational costs. A higher hashrate can reduce $/GH and lead to faster ROI, especially with low $/GH/m.
0 Reply Quote Share
ape2013Senior Member
Posts: 59 · Reputation: 1641
#19Aug 25, 2017, 04:16 AM
I disagree. Right now, it's best to run it at full speed for max W/GH. I’m aiming for 4TH/s at 2.3kW.
6 Reply Quote Share
grimb1tMember
Posts: 2 · Reputation: 73
#20Aug 25, 2017, 09:31 AM
If you have two circuits, just grab the right cables and you're set. Even at 3kW, you won’t exceed 12-13A at 240V, which is safe on a 20A circuit.
4 Reply Quote Share